How To Install A Sleeve Stop And Thimble Set

Posted on  by admin

#1-SC Multi-Groove Hand Swaging Tool for 1/16”, 3/32', 1/8', 5/32, & 3/16'Cable splicing is much easier if the cable is cut clean without frayed ends. We highly recommend C7, C9, C12 or C16 cable cutters as shown in the Loos & Co. Cableware Division catalog. LOCOLOC® Oval and Stop sleeves in a complete range of sizes are available through the Loos & Co. Cableware Division.Sleeves elongate after compression. To assure maximum holding allow the end of the cable to extend beyond the sleeve after it is com- pressed (see illustration below). Keep the jaws of the swager at right angles to the sleeve being compressed, making sure the sleeve is aligned in the jaw grooves.

  1. Ferrule And Stop Without Crimper
  2. How To Install A Sleeve Stop And Thimble Sets
  3. Cable Swage Tool

Then close the handles of the swager completely. (Note: for lap splices, at least two oval sleeves should be used.) Each Loos & Co. LOCOLOC® Swager is designed to work with one or more specific size sleeves. FOR USE ON ALL METAL CONSTRUCTION CABLES, 7x7, 7x19, 6x19 IWRC ON SIZES UP TO 5/16. You will not obtain performance if you do not use the proper swager and sleeve combination. T All compressions must be gauged to assure maximum holding strength, and it is recommended that all assemblies should be proof tested. SWAGER OPERATION INSTRUCTIONSFigure 1Place sleeve to be compressed in proper size groove in swaging tool.

Ferrule And Stop Without Crimper

Single cavity tools should match cable size to be swaged. Length of cable equal to the cable diameter should extend beyond length of sleeve to achieve maximum holding.

How

How To Install A Sleeve Stop And Thimble Sets

(See arrow in figure 3). Figure 4Use Swaging gauge provided with the tool to check proper after swage diameter. Compressed sleeve should slide freely into size slot of gauge.SWAGER OPERATION INSTRUCTIONSYour Loos & Co. LOCOLOC® Swager has been designed to give you years of trouble free service. Tower crane autocad block. To obtain the best possible performance, we recommend: (1) clean and lubricate all moving parts regularly; (2) keep all bolts tight; (3) keep your swager properly adjusted using the following simple procedure:Each LOCOLOC® Swager is supplied with a gauge.

Cable Swage Tool

Select the slot in the gauge corresponding to the sleeve size being compressed. The compressed portion of the sleeve should pass into the gauge easily. If it does not, then adjust your swager as follows:With the handles apart, use a 3/16' Allen wrench to tighten set screw in handle 1/4 turn. Then compress sleeve and check with the gauge. Continue this procedure until the compressed portion of the sleeve passes easily into the gauge. These instructions apply to all #1-SC, #0, #0-SC, and #1-BSC Loos & Co.

Rigging Supply 2019 CatalogWire Rope & Fittings CatalogWire Rope & Fittings Line CardCableRail Products by Feeney8-Page Feeney CableRail CatalogKONG Rescue & Safety EquipmentOmega Pacific Fire, Industrial and Safety & RescueOmega Pacific Climbing EquipmentGripple Hanger SolutionsGripple Hanger TypesGripple Complete ListingYoke 2014ABrochures & Flyers2016 Black Ops Product Line2017 Certified Product LineSpecifications & CertificationsISO CertificationU.S. RiggingOmega Pacific2018 Yoke Certs.